NIST Special Publication 800-171 Revision 2
Date Published: January 28th, 2021
Withdrawn on May 14, 2024. Superseded by SP 800-171 Rev. 3
Author(s): Ron Ross (NIST), Victoria Pillitteri (NIST), Kelley Dempsey (NIST), Mark Riddle (NARA), Gary Guissanie (IDA)
Note: A Class Deviation is in effect as of May 2, 2024 (DEVIATION 2024O0013). The deviation clause requires contractors, who are subject to 252.204-7012, to comply with National Institute of Standards and Technology (NIST) Special Publication (SP) 800-171 Revision 2, instead of the version of NIST SP 800-171 in effect at the time the solicitation is issued or as authorized by the contracting officer. Click Here
AC-3.1.18 Control connection of mobile devices
Control Family: Access Control
Control Type: Derived
SPRS Value: 5
SPRS Supplemental Guidance:
Do not subtract points if connection of mobile devices is not permitted
CMMC Level(s):
AC.L2-3.1.14
Top Ten Failed Requirement:
No
Referenced in:
DFARS 252.204-7012
Derived From: NIST SP 800-53r4
AC-19
NIST Supplemental Guidance:
[SP 800-124]
Discussion:
A mobile device is a computing device that has a small form factor such that it can easily be carried by a single individual; is designed to operate without a physical connection (e.g., wirelessly transmit or receive information); possesses local, non-removable or removable data storage; and includes a self-contained power source. Mobile devices may also include voice communication capabilities, on-board sensors that allow the device to capture information, or built-in features for synchronizing local data with remote locations. Examples of mobile devices include smart phones, e-readers, and tablets. Due to the large variety of mobile devices with different technical characteristics and capabilities, organizational restrictions may vary for the different types of devices. Usage restrictions and implementation guidance for mobile devices include: device identification and authentication; configuration management; implementation of mandatory protective software (e.g., malicious code detection, firewall); scanning devices for malicious code; updating virus protection software; scanning for critical software updates and patches; conducting primary operating system (and possibly other resident software) integrity checks; and disabling unnecessary hardware (e.g., wireless, infrared). The need to provide adequate security for mobile devices goes beyond this requirement. Many controls for mobile devices are reflected in other CUI security requirements. [SP 800-124] provides guidance on mobile device security
Upon assessment, assessors must determine if-
3.1.18[a] mobile devices that process, store, or transmit CUI are identified.
3.1.18[b] mobile device connections are authorized.
3.1.18[c] mobile device connections are monitored and logged.
Assessors are instructed to-
Examine: [SELECT FROM: Access control policy; authorizations for mobile device connections to organizational systems; procedures addressing access control for mobile device usage (including restrictions); system design documentation; configuration management plan; system security plan; system audit logs and records; system configuration settings and associated documentation; other relevant documents or records].
Interview: [SELECT FROM: Personnel using mobile devices to access organizational systems; system or network administrators; personnel with information security responsibilities].
Test: [SELECT FROM: Access control capability authorizing mobile device connections to organizational systems].
Potential Solutions Based on Staffing
1-10 FTE |
10-49 FTE |
50-249 FTE |
250-999 FTE |
1000+ FTE |
---|---|---|---|---|
WatchGuard Firebox UTM | WatchGuard Firebox UTM | WatchGuard Firebox UTM | Multiple Options | Multiple Options |
Netwrix Auditor | Netwrix Auditor | Netwrix Auditor | Netwrix Auditor | Netwrix Auditor |
Microsoft Intune | Microsoft Intune | Microsoft Intune | Microsoft Intune | Microsoft Intune |
DISA STIGs | DISA STIGs | Tripwire Enterprise | Tripwire Enterprise | Tripwire Enterprise |
CIS Benchmarks | CIS Benchmarks | DISA STIGs | DISA STIGs | DISA STIGs |
CIS SecureSuite | CIS SecureSuite | CIS Benchmarks | CIS Benchmarks | CIS Benchmarks |
CIS SecureSuite | CIS SecureSuite | CIS SecureSuite |