Note: A Class Deviation is in effect as of May 2, 2024 (DEVIATION 2024O0013). The deviation clause requires contractors, who are subject to 252.204-7012, to comply with National Institute of Standards and Technology (NIST) Special Publication (SP) 800-171 Revision 2, instead of the version of NIST SP 800-171 in effect at the time the solicitation is issued or as authorized by the contracting officer. Click Here
3.10.2: Protect and monitor the physical facility and support infrastructure for organizational systems.
Control Family: Physical Protection
Control Type: Basic
SPRS Value: 5
SPRS Supplemental Guidance: N/A
CMMC Level(s): PE.L2-3.10.2
Top Ten Failed Requirement:
No
Referenced in:
DFARS 252.204-7012
Derived From: NIST SP 800-53r4
PE-2
PE-4
PE-5
PE-6
NIST Supplemental Guidance:
N/A
Discussion:
Monitoring of physical access includes publicly accessible areas within organizational facilities. This can be accomplished, for example, by the employment of guards; the use of sensor devices; or the use of video surveillance equipment such as cameras. Examples of support infrastructure include system distribution, transmission, and power lines. Security controls applied to the support infrastructure prevent accidental damage, disruption, and physical tampering. Such controls may also be necessary to prevent eavesdropping or modification of unencrypted transmissions. Physical access controls to support infrastructure include locked wiring closets; disconnected or locked spare jacks; protection of cabling by conduit or cable trays; and wiretapping sensors.
Upon assessment, assessors must determine if-
3.10.2[a] the physical facility where organizational systems reside is protected.
3.10.2[b] the support infrastructure for organizational systems is protected.
3.10.2[c] the physical faciity where organizational systems reside is monitored.
3.10.2[d] the support infrastructure for organizational systems is monitored.
Assessors are instructed to-
Examine: [SELECT FROM: Physical and environmental protection policy; procedures addressing physical access monitoring; system security plan; physical access logs or records; physical access monitoring records; physical access log reviews; other relevant documents or records].
Interview: [SELECT FROM: Personnel with physical access monitoring responsibilities; personnel with incident response responsibilities; personnel with information security responsibilities].
Test: [SELECT FROM: Organizational processes for monitoring physical access; mechanisms supporting or implementing physical access monitoring; mechanisms supporting or implementing the review of physical access logs].
FURTHER DISCUSSION
The infrastructure inside of a facility, such as power and network cables, is protected so that visitors and unauthorized employees cannot access it. The protection is also monitored by security guards, video cameras, sensors, or alarms.
Example
You are responsible for protecting your IT facilities. You install video cameras at each entrance and exit, connect them to a video recorder, and show the camera feeds on a display at the reception desk [c,d]. You also make sure there are secure locks on all entrances, exits, and windows to the facilities [a,b].
Potential Assessment Considerations
Is physical access monitored to detect and respond to physical security incidents [c, d]?